Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [DW91KB] Travel Junction Sol Short

UEN00242-00 40 Troubleshooting Failure code [DW91KB] Travel Junction Sol Short 1 40 PC210, 230, 240-8 User code Failure code Trouble Travel junction solenoid system short (Pump controller system) — DW91KB Contents of trouble • When output to travel junction solenoid was turned ON, short circuit was detected in circuit. Action of controller • Turns output to travel junction solenoid OFF. • Even if cause of failure disappears, system does not reset itself until starting switch is turned OFF. Problem that appears on machine • Machine is not steered easily during travel. Related infor- mation • Operating condition of travel junction solenoid can be checked with monitoring function. (Code:

02300 Solenoid 1) • Method of reproducing failure code: Start engine + Steer machine with right and left travel levers. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective travel junction solenoid (Internal short cir- cuit or ground fault) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. V05 (male) Resistance Between (1) – (2) 20 – 60 z Between (1) – chassis ground Min. 1 Mz 2 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

Wiring harness between C02 (female) (110) – V05 (female) (1) Resis- tance Min. 1 Mz 3 Defective pump controller a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. C02 (female) Resistance Between (110) – (115), (117), (120) 20 – 60 z Between (110) – chassis ground Min. 1 Mz