UEN00243-00 40 Troubleshooting Troubleshooting by failure code (Display of code), Part 4 1 Failure code [DXA8KA] PC-EPC (F) Sol Discon 1 4 PC210, 230, 240-8 User code Failure code Trouble PC-EPC (F) solenoid system disconnection (Pump controller system) E02 DXA8KA Contents of trouble • When PC-EPC (F) solenoid was driven, disconnection was detected in circuit. Action of controller • None in particular (Since no current flows, solenoid does not operate). • If cause of failure disappears, system resets itself. Problem that appears on machine • If pump load increases, engine speed lowers largely and engine may stall.
Related infor- mation • Drive current of PC-EPC (F) solenoid can be checked with monitoring function. (Code: 01300 PC-EPC solenoid current (F)) • Method of reproducing failure code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective PC-EPC (F) sole- noid (Internal disconnection) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
V11 (male) Resistance Between (1) – (2) 7 – 14 z 2 Defective emergency pump drive switch (Internal discon- nection) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. S25 (male) Emergency pump drive switch Resistance Between (3) – (2) Normal Max. 1 z Emergency Min. 1 Mz Between (6) – (5) Normal Max. 1 z Emergency Min. 1 Mz 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between C02 (female) (96) – S25 (female) (3) Resis- tance Max.
1 z Wiring harness between S25 (female) (2) – V11 (female) (1) Resis- tance Max. 1 z Wiring harness between C02 (female) (115), (117), (120) – S25 (female) (6) Resis- tance Max. 1 z Wiring harness between S25 (female) (5) – V11 (female) (2) Resis- tance Max. 1 z 4 Defective pump controller a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. C02 (female) Resistance Between (96) – (115), (117), (120) 7 – 14 z