UEN00243-00 40 Troubleshooting Failure code [DXA8KB] PC-EPC (F) Sol Short 1 6 PC210, 230, 240-8 User code Failure code Trouble PC-EPC (F) solenoid system short (Pump controller system) E02 DXA8KB Contents of trouble • When PC-EPC (F) solenoid was driven, short circuit was detected in circuit. Action of controller • Turns output to PC-EPC (F) solenoid OFF. • Even if cause of failure disappears, system does not reset itself until starting switch is turned OFF. Problem that appears on machine • If pump load increases, engine speed lowers largely and engine may stall. Related infor- mation • Drive current of PC-EPC (F) solenoid can be checked with monitoring function. (Code:
01300 PC-EPC solenoid current (F)) • Method of reproducing failure code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective PC-EPC (F) sole- noid (Internal short circuit or ground fault) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. V11 (male) Resistance Between (1) – (2) 7 – 14 z Between (1) – chassis ground Min. 1 Mz 2 Defective emergency pump drive switch (Internal short circuit or ground fault) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
S25 (male) Emergency pump drive switch Resistance Between (2), (3) – (4) Normal Min. 1 Mz Between (2), (3) – chassis ground Min. 1 Mz 3 Ground fault in wiring har- ness (Contact with GND cir- cuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between C02 (female) (96) – S25 (female) (3) Resis- tance Min. 1 Mz Wiring harness between S25 (female) (5) – V11 (female) (2) Resis- tance Min. 1 Mz 4 Defective pump controller a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. C02 (female) Resistance Between (96) – (115), (117), (120) 7 – 14 z Between (96) – chassis ground Min.
1 Mz