Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [DXA9KA] PC-EPC (R) Sol Discon

UEN00243-00 40 Troubleshooting Failure code [DXA9KA] PC-EPC (R) Sol Discon 1 8 PC210, 230, 240-8 User code Failure code Trouble PC-EPC (R) solenoid system disconnection (Pump controller system) E02 DXA9KA Contents of trouble • When PC-EPC (R) solenoid was driven, disconnection was detected in circuit. Action of controller • None in particular (Since no current flows, solenoid does not operate). • If cause of failure disappears, system resets itself. Problem that appears on machine • If pump load increases, engine speed lowers largely and engine may stall. Related infor- mation • Drive current of PC-EPC (R) solenoid can be checked with monitoring function. (Code:

01302 PC-EPC solenoid current (R)) • Method of reproducing failure code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective PC-EPC (R) sole- noid (Internal disconnection) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. V12 (male) Resistance Between (1) – (2) 7 – 14 z 2 Defective emergency pump drive switch (Internal discon- nection) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. S25 (male) Emergency pump drive switch Resistance Between (9) – (8) Normal Max. 1 z Emergency Min.

1 Mz Between (12) – (11) Normal Max. 1 z Emergency Min. 1 Mz 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between C02 (female) (104) – S25 (female) (9) Resis- tance Min. 1 Mz Wiring harness between S25 (female) (8) – V12 (female) (1) Resis- tance Min. 1 Mz Wiring harness between C02 (female) (115), (117), (120) – S25 (female) (12) Resis- tance Min. 1 Mz Wiring harness between S25 (female) (11) – V12 (female) (2) Resis- tance Min.

1 Mz 4 Defective pump controller a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. C02 (female) Resistance Between (104) – (115), (117), (120) 7 – 14 z