Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [DXE4KA] Service Current EPC Discon

UEN00243-00 40 Troubleshooting Failure code [DXE4KA] Service Current EPC Discon 1 16 PC210, 230, 240-8 User code Failure code Trouble Service current EPC solenoid disconnection (Pump controller system) — DXE4KA Contents of trouble • When service EPC solenoid was driven, disconnection was detected in circuit. Action of controller • None in particular (Since no current flows, solenoid does not operate). • If cause of failure disappears, system resets itself. Problem that appears on machine • Attachment does not operate. Related infor- mation • Drive current of service EPC solenoid can be checked with monitoring function. (Code:

01700 service solenoid current) • Method of reproducing failure code: Turn starting switch ON + Set in attachment mode (ATT). Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective service EPC sole- noid (Internal disconnection) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. V30 (male) Resistance Between (1) – (2) 7 – 14 z 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

Wiring harness between C02 (female) (97) – V30 (female) (1) Resis- tance Max. 1 z Wiring harness between C02 (female) (115), (117), (120) – V30 (female) (2) Resis- tance Max. 1 z 3 Defective pump controller a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. C02 (female) Resistance Between (97) – (115), (117), (120) 7 – 14 z