UEN00243-00 40 Troubleshooting Failure code [DXE6KA] Merge-divider LS Sol Discon 1 24 PC210, 230, 240-8 User code Failure code Trouble Merge-divider LS solenoid disconnection (Pump controller system) — DXE6KA Contents of trouble • When merge-divider LS EPC solenoid was driven, disconnection was detected in circuit. Action of controller • None in particular (Since no current flows, solenoid does not operate). • If cause of failure disappears, system resets itself. Problem that appears on machine • Single operation speed of work equipment and swing is high in lifting mode (L). Related infor- mation • Drive current of merge-divider LS EPC solenoid can be checked with monitoring function. (Code:
08001 merge-divider LS solenoid current) • Method of reproducing failure code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective merge-divider LS EPC solenoid (Internal dis- connection) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. V24 (male) Resistance Between (1) – (2) 7 – 14 z 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
Wiring harness between C02 (female) (89) – V24 (female) (1) Resis- tance Max. 1 z Wiring harness between C02 (female) (115), (117), (120) – V24 (female) (2) Resis- tance Max. 1 z 3 Defective pump controller a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. C02 (female) Resistance Between (89) – (115), (117), (120) 7 – 14 z