Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [DXE6KB] Merge-divider LS Sol Short

UEN00243-00 40 Troubleshooting Failure code [DXE6KB] Merge-divider LS Sol Short 1 26 PC210, 230, 240-8 User code Failure code Trouble Merge-divider LS solenoid short (Pump controller system) — DXE6KB Contents of trouble • When merge-divider LS EPC solenoid was driven, short circuit was detected in circuit. Action of controller • Turns output to merge-divider LS EPC solenoid OFF. • Even if cause of failure disappears, system does not reset itself until starting switch is turned OFF. Problem that appears on machine • Single operation speed of work equipment and swing is re high in lifting mode (L).

Related infor- mation • Drive current of merge-divider LS EPC solenoid can be checked with monitoring function. (Code: 08000 merge-divider LS EPC solenoid current) • Method of reproducing failure code: Turn starting switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective merge-divider LS EPC solenoid (Internal short circuit or ground fault) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. V24 (male) Resistance Between (1) – (2) 7 – 14 z Between (1) – chassis ground Min.

1 Mz 2 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between C02 (female) (89) – V24 (female) (1) Resis- tance Min. 1 Mz 3 Defective pump controller a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. C02 (female) Resistance Between (89) – (115), (117), (120) 7 – 14 z Between (89) – chassis ground Min. 1 Mz