UEN00243-00 40 Troubleshooting Failure code [DY2CKA] Washer Drive Discon 1 32 PC210, 230, 240-8 User code Failure code Trouble Window washer drive system disconnection (Pump controller system) — DY2CKA Contents of trouble • When output to window washer drive system was turned OFF (when ground circuit was connected), disconnection was detected in circuit. Action of controller • None in particular (Since no current flows, washer motor does not operate). • If cause of failure disappears, system resets itself. Problem that appears on machine • Window washer does not operate. Related infor- mation • Method of reproducing failure code: Turn starting switch ON.
Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuse No. 4 If fuse is broken, circuit probably has ground fault. (See cause 5.) 2 Defective washer motor (Internal short circuit or ground fault) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. M06 (male) Resistance Between (1) – (2) 5 – 20 z Between (1), (2) – chassis ground Min. 1 Mz 3 Defective assembled-type diode D02 (Internal short cir- cuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
D02 (female) Continuity (Resistance) Between (3) – (7) No continuity (Min. 1 Mz) 4 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between F01 (4) – J03 – M06 (female) (1) Resis- tance Max. 1 z Wiring harness between C01 (female) (3) – J04 – M06 (female) (2) Resis- tance Max. 1 z 5 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
Wiring harness between F01 (4) – J03 – M06 (female) (1), – D02 (female) (3) Resis- tance Min. 1 Mz Wiring harness between C01 (female) (3) – J04 – M06 (female) (2), – D02 (female) (7) Resis- tance Min. 1 Mz 6 Defective pump controller a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. C01 (female) Voltage Between (3) – chassis ground 20 – 30 V