Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — Failure code [DY2CKB] Washer Drive Short

UEN00243-00 40 Troubleshooting Failure code [DY2CKB] Washer Drive Short 1 34 PC210, 230, 240-8 User code Failure code Trouble Window washer drive system short (Pump controller system) — DY2CKB Contents of trouble • When output to window washer drive system was turned ON (ground circuit was disconnected), short circuit was detected in circuit. Action of controller • Turns output to washer motor OFF. • Even if cause of failure disappears, system does not reset itself until starting switch is turned OFF. Problem that appears on machine • Window washer does not operate. Related infor- mation • Method of reproducing failure code: Turn starting switch ON + Turn washer switch ON.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective washer motor (Internal short circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. M06 (male) Resistance Between (1) – (2) 5 – 20 z 2 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between C01 (female) (3) – J04 – M6 (female) (2), – D02 (female) (7) Voltage Max. 1 V 3 Defective pump controller If causes 1 and 2 are not detected, pump controller may be defec- tive.

(Since trouble is in system, troubleshooting cannot be carried out.)