Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — E-4 Preheater does not operate

UEN00244-00 40 Troubleshooting E-4 Preheater does not operate 1 14 PC210, 230, 240-8 Trouble (1) When starting switch is turned to HEAT position, preheating monitor does not light up or flash. Related informa- tion • Preheater monitor lights up when starting switch is turned to HEAT and starts flashing about 30 seconds after to notify completion of preheating (It stops flashing about 10 seconds after). • If engine coolant temperature is below 20°C, automatic warm-up system operates and preheating monitor lights up for up to 30 seconds. • Condition of starting switch (preheating) signal can be checked with the monitoring function. (Code:

04500 Monitor input 1) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective starting switch (Inter- nal disconnection) a Prepare with starting switch OFF, then keep starting switch OFF and turn it to HEAT and carry out troubleshooting in each case. H15 (male) Starting switch Resistance Between (1) – (3) OFF Min. 1 Mz HEAT Max. 1 z 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in connec- tor) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CM01 (female) (16) – J02 – H15 (female) (3) Resis- tance Max.

1 z 3 Defective machine monitor a Prepare with starting switch OFF, then keep starting switch OFF and turn it to HEAT and carry out troubleshooting in each case. CE02 Starting switch Voltage Between (16) – chassis ground OFF Max. 1 V HEAT 20 – 30 V Trouble (2) When starting switch is turned to HEAT position, intake air heater mounting part does not become warm. Related informa- tion • Check that engine can be turned with starting motor (If engine cannot be turned, carry out troubleshooting for E-1 Engine does not start (Engine does not turn)).

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective heater relay (Internal disconnection) a Prepare with starting switch OFF (with wiring harness connected), then keep starting switch OFF and turn it to HEAT and carry out troubleshooting in each case. Heater relay Starting switch Continuity/Resistance Between R15 – chassis ground OFF There is continuity Between power supply terminal – R16 HEAT Max. 1 z 2 Defective intake air heater (Internal disconnection) a Prepare with starting switch OFF (with wiring harness connected), then turn starting switch to HEAT and carry out troubleshooting in each case.

E01 Starting switch Voltage Between terminal – chassis ground HEAT 20 – 30 V If voltage is normal but heater mounting part does not become warm, intake air heater is defective. 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in connec- tor) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between H15 (female) (3) – J02 – heater relay R15 Resis- tance Max. 1 z Wiring harness between battery relay R03 – heater relay contact terminal Resis- tance Max. 1 z Wiring harness between heater relay R16 – intake air heater E01 Resis- tance Max. 1 z