Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — E-7 Precaution lights up while engine is running

UEN00244-00 40 Troubleshooting E-7 Precaution lights up while engine is running 1 20 PC210, 230, 240-8 Trouble (1) Charge level monitor lights up red. Related infor- mation • Signal voltage of alternator can be checked with monitoring function. (Code: 04300 Charge voltage) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective generation by alternator (when system is normal) a Prepare with starting switch OFF, then start engine and carry out troubleshooting.

E12 (male) Engine speed Voltage Between (1) – chas- sis ground Middle or higher 27.5 – 29.5 V 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CM01 (female) (11) – J02 – E12 (female) (1) Resis- tance Max. 1 z 3 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between CM01 (female) (11) – J02 – E12 (female) (1), – circuit branch end Resis- tance Min.

1 Mz 4 Defective machine monitor a Prepare with starting switch OFF, then start engine and carry out troubleshooting. CM02 Engine Voltage Between (11) – chassis ground Running Min. 7.8 V