40 Troubleshooting UEN00244-00 E-10 Hydraulic oil temperature gauge does not indicate normally 1 Circuit diagram related to hydraulic oil temperature sensor PC210, 230, 240-8 27 Trouble (1) While hydraulic oil temperature is rising normally, temperature gauge does not rise from white range (C). (2) While hydraulic oil temperature is stabilized normally, temperature gauge rises to red range (H). Related infor mation • Signals of hydraulic oil temperature sensor are input to pump controller and then transmitted to - machine monitor through communication system. • Hydraulic oil temperature can be checked with monitoring function. (Code:
04401 Hydraulic oil temperature) Possible cause and standard value in norm state Cause Defective hydraulic oil tem- 1 perature sensor (Internal dis- connection or short circuit) Disconnection in wiring har- ness (Disconnection in wiring 2 or defective contact in con- nector) s Ground fault in wiring har- al 3 ness (Short circuit with GND circuit) Hot short (Short circuit with 4 24V circuit) in wiring harness 5 Defective pump controller 6 Defective machine monitor Standard value in normal state/Remarks on troubleshooting a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
P22 (male) Resistance Between (1) – (2) 3.5 – 90 kz Between (2) – chassis ground Min. 1 Mz a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between C01 (female) (29) – P22 (female) (2) Resis- tance Max. 1 z Wiring harness between C01 (female) (46) – P22 (female) (1) Resis- tance Max. 1 z a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between C01 (female) (29) – P22 (female) (2) Resis- tance Min. 1 Mz a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting.
Wiring harness between C01 (female) (29) – P22 (female) (2) Voltage Max. 1 V a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. C01 (female) Resistance Between (29) – (46) 3.5 – 90 kz Between (29) – chassis ground Min. 1 Mz If causes 1 – 5 are not detected, machine monitor may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)