UEN00244-00 40 Troubleshooting E-20 Power maximizing function does not operate normally 1 Circuit diagram related to left knob switch 38 PC210, 230, 240-8 Trouble (1) When left knob switch is pressed, one-touch power maximizing monitor is not displayed. (2) When left knob switch is pressed, work equipment power is not increased. Related infor- mation • One-touch power maximizing function does not work when working mode is not power mode (P) or economy mode (E). • Condition of left knob switch signal can be checked with monitoring function. (Code:
02200 Switch input 1) Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuse No. 9 If fuse is broken, circuit probably has ground fault. (See cause 4.) Defective left knob switch 2 (Internal disconnection) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. S11 (male) Left knob switch Resistance Between (1) – (2) Released Min. 1 Mz Pressed Max. 1 z Disconnection in wiring har- ness (Disconnection in wiring 3 or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
Wiring harness between F01-9 – S11 (female) (1) Resis- tance Max. 1 z Wiring harness between S11 (female) (2) – C01 (female) (41) Resis- tance Max. 1 z Ground fault in wiring har- 4 ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between F01-9 – S11 (female) (1) Resis- tance Min. 1 Mz Wiring harness between S11 (female) (2) – C01 (female) (41) Resis- tance Min. 1 Mz 5 Defective pump controller a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. C01 (female) Left knob switch Resistance Between (41) – chassis ground Released Min.
1 Mz Pressed Max. 1 z 6 Defective machine monitor Machine monitor may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)