UEN00244-00 40 Troubleshooting E-22 Travel alarm does not sound or does not stop sounding 1 42 PC210, 230, 240-8 Trouble (1) Alarm does not sound during travel. Related infor- mation Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective fuse No. 15 If fuse is broken, circuit probably has ground fault. (See cause 4.) 2 Defective travel signal sys- tem a Start engine and carry out troubleshooting. Monitoring code Item Normal display 01900 Pressure switch 1 Travel When lever is operated: ON When lever is in neutral:
OFF If display of monitoring is abnormal, carry out troubleshooting for E-26 Monitoring function does not display lever control signal nor- mally. 3 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between F01-15 – J03 – M14 (female) (1) Resis- tance Max. 1 z Wiring harness between M14 (female) (2) – J01 (19) – P09 (female) (2) Resis- tance Max. 1 z 4 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.
Wiring harness between F01-15 – J03 – M14 (female) (1), – circuit branch end Resis- tance Min. 1 Mz 5 Defective travel alarm (Inter- nal defect) If causes 1 – 4 are not detected, travel alarm is defective. Trouble (2) Alarm does not stop sounding while machine is stopped. Related infor- mation Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective travel signal sys- tem a Start engine and carry out troubleshooting. Monitoring code Item Normal display Pressure switch 1 Travel When lever is oper- ated: ON When lever is in neu- tral:
OFF If display of monitoring is abnormal, carry out troubleshooting for E- 26 Monitoring function does not display lever control signal nor- mally. 2 Defective assembled-type diode D05 (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. D02 (male) Continuity Between (4) – (8) No continuity 3 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between M14 (female) (2) – J01 (19) – P09 (female) (2), – D02 (female) (4) Resis- tance Min. 1 Mz