Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — E-23 Air conditioner does not operate normally (including air conditioner abnormality record)

UEN00244-00 40 Troubleshooting 50 PC210, 230, 240-8 Trouble (8) Air conditioner abnormality record: External air sensor “Unused” Related infor- mation • External air sensor is not used in air conditioner system of this machine. • If “CAN disconnection” is displayed as communication condition, communication cannot be carried out normally. Accordingly, this condition is not displayed. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Normal display Since external air sensor is not used in air conditioner system of this machine, above display is normal. Trouble (9) Air conditioner abnormality record:

Air flow sensor “Abnormality” Related infor- mation • If “CAN disconnection” is displayed as communication condition, communication cannot be carried out normally. Accordingly, this condition is not displayed. • Method of reproducing abnormality record: Turn starting switch ON + Turn air conditioner (A/C) switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective air flow sensor (Internal disconnection or short circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON.

THF (device side) Resistance Between (1) – (2) 100 z – 115 kz 2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between ACW (wiring side) (12) – THF (wiring side) (2) Resis- tance Max. 1 z Wiring harness between ACW (wiring side) (27) – THF (wiring side) (1) Resis- tance Max. 1 z 3 Short circuit in wiring har- ness (with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between ACW (wiring side) (12) – THF (wiring side) (2) Resis- tance Min.

1 Mz 4 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between ACW (wiring side) (12) – THF (wiring side) (2) Voltage Max. 1 V 5 Defective air conditioner con- troller If causes 1 – 4 are not detected, air conditioner controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)