Komatsu PC210-8, PC210LC-8, PC210NLC-8, PC230NHD-8, PC240LC-8, PC240NLC-8 — E-23 Air conditioner does not operate normally (including air conditioner abnormality record)

UEN00244-00 40 Troubleshooting 52 PC210, 230, 240-8 Trouble (11) Air conditioner abnormality record: Air outlet damper “Abnormality” Related infor- mation • If “CAN disconnection” is displayed as communication condition, communication cannot be carried out normally. Accordingly, this condition is not displayed. • Method of reproducing abnormality record: Turn starting switch ON + Turn air conditioner (A/C) switch ON. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Defective air outlet servo- motor (Internal defect) Air outlet servomotor may be defective.

2 Disconnection in wiring har- ness (Disconnection in wiring or defective contact in con- nector) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between MV1 (wiring side) (1) – ACW (wiring side) (3) Resis- tance Max. 1 z Wiring harness between MV1 (wiring side) (3) – ACW (wiring side) (27) Resis- tance Max. 1 z Wiring harness between MV1 (wiring side) (5) – ACW (wiring side) (9) Resis- tance Max. 1 z Wiring harness between MV1 (wiring side) (6) – ACW (wiring side) (24) Resis- tance Max. 1 z Wiring harness between MV1 (wiring side) (7) – ACW (wiring side) (23) Resis- tance Max.

1 z 3 Ground fault in wiring har- ness (Short circuit with GND circuit) a Prepare with starting switch OFF, then carry out troubleshooting without turning starting switch ON. Wiring harness between MV1 (wiring side) (1) – ACW (wiring side) (3), – circuit branch end Resis- tance Min. 1 Mz Wiring harness between MV1 (wiring side) (5) – ACW (wiring side) (9), – circuit branch end Resis- tance Min. 1 Mz Wiring harness between MV1 (wiring side) (6) – ACW (wiring side) (24), – circuit branch end Resis- tance Min. 1 Mz Wiring harness between MV1 (wiring side) (7) – ACW (wiring side) (23), – circuit branch end Resis- tance Min.

1 Mz 4 Hot short (Short circuit with 24V circuit) in wiring harness a Prepare with starting switch OFF, then turn starting switch ON and carry out troubleshooting. Wiring harness between MV1 (wiring side) (1) – ACW (wiring side) (3), – circuit branch end Voltage Max. 1 V Wiring harness between MV1 (wiring side) (5) – ACW (wiring side) (9), – circuit branch end Voltage Max. 1 V Wiring harness between MV1 (wiring side) (6) – ACW (wiring side) (24), – circuit branch end Voltage Max. 1 V Wiring harness between MV1 (wiring side) (7) – ACW (wiring side) (23), – circuit branch end Voltage Max.

1 V 5 Defective air conditioner con- troller If causes 1 – 4 are not detected, air conditioner controller may be defective. (Since trouble is in system, troubleshooting cannot be carried out.)