UEN00099-00 10 Structure, function and maintenance standard Hydraulic tank and filter 1 ( PC240 shown ) 1. Hydraulic tank 2. Oil filler port cap 3. Filter element 4. Strainer 5. Bypass valve 6. Suction strainer 7. Sight gauge Safety valve Relief cracking pressure: 16.7 ± 6.9 kPa {0.17 ± 0.07 kg/cm 2 } Suction cracking pressure: 0 – 0.49 kPa {0 – 0.005 kg/cm 2 } Bypass valve set pressure: 150 ± 30 kPa {1.5 ± 0.3 kg/cm 2 } Specifications PC240 PC210 / 230 Tank capacity 190 L 192 L Amount of oil inside tank 135 L 137 L 4 PC210, 230, 240-8