10 Structure, function and maintenance standard UEN00099-00 Outline q This pump consists of 2 variable capacity swash plate piston pumps, PC valve, LS valve, and EPC valve. IMF : Front PC mode selector current IMR : Rear PC mode selector current ISIG : LS set pressure selector current PAF : Front pump delivery port PAR : Rear pump delivery port PBF : Pump pressure input port PD1F : Case drain port (PC240) PD1R (PC210 / 230) PD1R : Air bleeder PD2F : Drain plug PD2R : Drain plug PENF : Front control pressure detection port PENR : Rear control pressure detection port PEPC : EPC basic pressure port PEPCC : EPC basic pressure detection port PFC :
Front pump delivery pressure detection port PLSF : Front load pressure input port PLSFC : Front load pressure detection port PLSR : Rear load pressure input port PLSRC : Rear load pressure detection port PMF : Front PC mode selector pressure detec- tion port PMR : Rear PC mode selector pressure detec- tion port PRC : Rear pump discharge pressure detection port PS : Pump suction port PSIG : LS set selector pressure detection port 1. Front pump 2. Rear pump 3. LS valve 4. PC valve 5. LS-EPC valve 6. PC-EPC valve PC210, 230, 240-8 7