OPERATION 3.4 ELECTRONIC MONITORING AND CONTROL SYSTEM ECS Menu Control with Key Switch (C) and Key Group (D) Display of system pressures, menu item Service *POWER CHECK* Starting from the menu level -1-, *SERVICE* see menu control charts I and II. Proceed as follows: 1. Select menu level -1- by pressing ”QUI” key (10) the starting menu item *Truck counter reading:* appears on the display, see chart I. Press key (12) three times, the main group *SERVICE* is dis- played. Press key (10), level -2- with menu item *LAN- GUAGE* appears on the display. 2. Press key (12) once, the menu point *POWER CHECK* appears on the display. 3.
Press key (10), Power Check *DISPLAY* in level 3, see chart II appears on the display. 4. Press key (10) for display of the present system pressures in level 4. 5. For returning to the standard display level -0- press ”RET” key (9) four times. Adjust hydraulic oil cooler fan speed Within the menu point *POWER CHECK* the fan speed of the hydraulic oil coolers can be set to minimum or maximum speed as follows: Select menu point Power Check *FAN DRIVE OIL COOLER MIN / MAX* in level 3, chart II. Press key (10) the present speed condi- tion of the cooler fans appears on the display in level 4.
To change the fan speed insert service key (C) and select with keys (11 and 12) the condition for minimum speed as shown in display (A) or for maximum speed as shown in display (B). For display of the system pressures with the adjusted fan speed press key (9) the menu point Power Check *FAN DRIVE OIL COOLER MIN / MAX* in level 3 appears on the screen. Select menu point Power Check *DISPLAY* with key (D) then press key (10) the current system pressures are now displayed in level 4.
Resetting oil cooler fan speed to normal condition For resetting the fan speed to normal condition (Evaluation ON) switch off key switch (C) or go back to menu point *SERVICE* in level 1 by pressing the Return key (9) three times. 133