OPERATION 3.4 ELECTRONIC MONITORING AND CONTROL SYSTEM ECS Menu Control with Key Switch (C) and Key Group (D) Setting of Operational Data, menu item Service *SETTINGS* Example: Changing the pause time of the Central Lubrication System. Starting from the menu level -1-, *SERVICE* see menu control charts I and III. Proceed as follows: 1. Select menu level -1- by pressing ”QUI” key (10) the starting menu item *Truck counter reading:* appears on the display, see chart I. Press key (12) three times, the main group *SERVICE* is dis- played. Press key (10), level -2- with menu item *LAN- GUAGE* appears on the display. 2. Press key (12) three times, the menu point *SETTINGS appears on the display.
3. Press key (10), *PTO GEAR-OIL VISCOSITY* in level 3, see chart III appears on the display. 4. Press key (12) two times, the item *CENTRAL LUBRICATION SYSTEM* is displayed. 5. Press key (10), level 4 with the starting menu item *CONDI- TION INDICATION* appears on the display. 6. Press key (12) once, the display changes tto menu item *PAUSE TIME* with the information of the present *PAUSE TIME (e.g.) 01:00* appears on the display. 7. Press key (10) again, the display changes to level 5 with the information ”Settings OPERATE KEY SWITCH”. 8. Operate key switch (C), now the ”pause time: 01:00” ”new pause time: 01:00 ” is displayed. 9.
Use key (4) of the Text display keyboard to position the cursor below the numerical value that shall be changed. 10. Use key (2 and/or 3) ”UP/DOWN” of the Text display key- board for changing the numerical value. 11. Acknowledge the new setting by pressing key (1). The infor- mation on the display changes over to the introductory mes- sage page -0- or if a message is present to the respective message page. 137