Komatsu — 3.4.5 MENU CONTROL LIST

3.4 ELECTRONIC MONITORING AND CONTROL SYSTEM ECS OPERATION Level 4: Inputs - Outputs / DIGITAL-OUTPUTS / K164-1 RELAY ENGINE OIL TANK 1 EMPTY -4- Output signals | OPERATE KEY SWITCH -4- Relay engine oil tank 1 empty | 0 | 1 | K164-1 (A7.7): Level 4: Inputs - Outputs / DIGITAL-OUTPUTS / K164-2 RELAY ENGINE OIL TANK 2 EMPTY -4- Output signals | OPERATE KEY SWITCH -4- Relay engine oil tank 2 empty | 0 | 1 | K164-2 (A7.8): Level 4: Inputs - Outputs / DIGITAL-OUTPUTS / K197 RELAY LOWER WINDSCREEN WIPER SLOW -4- Output signals | OPERATE KEY SWITCH -4- Relay Lower windscreen wiper slow | 0 | 1 | K197 (A13.5): Level 4:

Inputs - Outputs / DIGITAL-OUTPUTS / K198 RELAY LOWER WINDSCREEN WIPER FAST -4- Output signals | OPERATE KEY SWITCH -4- Relay Lower windscreen wiper fast | 0 | 1 | K198 (A13.8): Level 4: Inputs - Outputs / DIGITAL-OUTPUTS / K199 RELAY UPPER WINDSCREEN WIPER SLOW -4- Output signals | OPERATE KEY SWITCH -4- Relay Upper windscreen wiper slow | 0 | 1 | K199 (A13.6): 170