Komatsu — 3.4.6 FAULT AND INFORMATION MESSAGE LIST

OPERATION 3.4 ELECTRONIC MONITORING AND CONTROL SYSTEM ECS Fault and Information Message List GROUP 1 Fault Message Texts of message pages No. 500 - 731 Fault No. 500: (503) *1) $h: Start blocked through main Shut-Off (gate) valve Help: Limit switch S31 not closed. - Check for broken cables to switch S31. Fault No. 506: (509) $h: Start of engine 1 blocked by high pressure filter #1 Help: Differential pressure switch B5-1 not closed. - Check cables to differential pressure switch B5-1. Fault No. 512: (515) $h: Shutdown: CENSE ECM indicates major fault of engine 1 Help: Fault No. 518: (521) $h: Shutdown: CENSE ECM indicates major fault of engine 2 Help: Fault No. 524: (527) $h:

High pressure filter #1 restricted. Stop the engine 1 Help: Differential pressure switch B5-1 not closed. - Clean or replace filter element. - Check pump Fault No. 530: (533) $h: Help: . *1) Numbers in brackets are the message page numbers of the second language. 175