3.4 ELECTRONIC MONITORING AND CONTROL SYSTEM ECS OPERATION Fault No. 728: (731) $h: Short circuit at PLC output group A1.X A3.X A5.X A7.X A13.X Help: - MK-LED indicates the output group. - Check cables at the output group. GROUP 2 Fault Message Texts of message pages No. 734 - 1309 will be stored Fault No. 734: (737) $h: Faulty monitor channel for pump #1/5 pressure Help: Pressure pick up B87A for the pump #1/5 pressure shows inadmissible values. - Check sensor and cables. Fault No. 740: (743) $h: Faulty monitor channel for pump #2/6 pressure Help: Pressure pick up B87B for the pump #2/6 pressure shows inadmissible values. - Check sensor and cables. Fault No. 746 (749) $h:
Faulty monitor channel for pump #3/7 pressure Help: Pressure pick up B87C for the pump #3/7 pressure shows inadmissible values. - Check sensor and cables. Fault No. 752: (755) $h: Faulty monitor channel for pump #4/8 pressure Help: Pressure pick up B87D for the pump #4/8 pressure shows inadmissible values. - Check sensor and cables. Fault No. 758: (761) $h: Faulty pressure switch for strainer oil cooler Help: Closed contact of pressure switch B165 of return oil strainer with switched off engine. - Check pressure switch and cables. 180