OPERATION 3.4 ELECTRONIC MONITORING AND CONTROL SYSTEM ECS Fault No. 1220: (1223) $h: Help: Fault No. 1226: (1229) $h: Help: Fault No. 1232: (1235) $h: Shutdown through emergency stop switch S36. Help: Emergency stop switch S36 in the cab actuated. - Find cause Fault No. 1238: (1241) $h: Shutdown through maintenance safety switch S58. Help: Maintenance safety switch S58 in machinery house actu- ated. - Find cause Fault No. 1244: (1247) $h: Faulty monitor channel for level central lube sys- tem. Help: Level sensor B108 shows inadmissible values. - Check monitor channel and sensor. Fault No. 1250: (1253) $h: Bucket motion switched off due to lubrication system failure Help:
Automatic lubrication suspended for 4 hours. - Perform manually actuated lubrication. - Repair lubrication system. Fault No. 1256: (1259) $h: Faulty switch hydraulic oil level or lack of hydraulic oil Help: Stop the engines. - Check level sensor B4 and B50. - Check hydraulic oil level. Fault No. 1262: (1265) $h: Lack of hydraulic oil ! Fill up hydraulic oil ! Help: Hydraulic oil level too low. - Fill up hydraulic oil. (indicated by B4) 191