Komatsu — 3.6.2 BATTERY MAIN SWITCHES AND SAFETY SWITCH FOR MAINTENANCE

OPERATION 3.6 MACHINERY HOUSE 3.6.2 BATTERY MAIN SWITCHES AND SAFETY SWITCH FOR MAINTENANCE Legend for illustration Z26303 (1) Maintenance safety switch for start prevention of the engines (2) Rotary switch Switch positions: -0- Engine start blocked -1- Normal operation (3) Securing flap for rotary switch in -0- position (4) Holes for attaching padlocks Before beginning any maintenance operations set the rotary switch (2) to -0- position to prevent starting of the engines during maintenance. Fold up flap (3) and secure this position by inserting a padlock into the holes (4) of flap (3) and safety switch (1). Up to ten padlocks can be attached.

(5) Battery main switch keys (6) Batteries located below the catwalk gratings (7) Hinged covers of the battery compartment (8) Battery fastening tie rods Before working on the batteries or any other part of the electrical system remove both battery main switch keys (5). Batteries give off highly inflammable gas! Never allow sparks or open flame near the batteries! Avoid spilling any electrolyte on hands or clothing. Repair or replace all broken wires immediately. All termi- nals must be clean and securely fastened; never paint connections. DO NOT short across or ground any terminals of the bat- teries.

For access to the batteries remove mounting bolts of covers (7) and open the hinged covers. Secure the open covers with the safety chains provided. 205 WARNING WARNING WARNING WARNING