OPERATION 3.6 MACHINERY HOUSE 3.6.3 CENTRAL CONTROL AND FILTER PANEL Legend for illustration Z21766 (1) Pump compartment doors (2) Safety rods (3) Door locking rods (4) Retainer sleeves on door posts Before opening a pump compartment door (1) make sure both safety rods (2) are installed and properly secured. Secure the doors in open position by engaging the locking rods (3) into the retainer sleeves on the door posts.
(5) Central control and filter panel (6) Valve bank (6.1) Load limit block for pump control circuit engine 1 (6.2) Load limit block for pump control circuit engine 2 (6.3) Pilot oil block (6.4) Pump control block (6.5) Travel circuit block (6.6) Swing circuit block (6.7) Hydraulic access ladder block (6.8) Hydraulic swing down service arm block (7.1) Change over valve for operation mode of pump control system engine 1 (7.2) Change over valve for operation mode of pump control system engine 2 E - Lever in electronic operation mode position (normal working order) H - Lever in hydraulic operation mode position (e.g.
for testing purposes) The standard operation mode of the pump control system is the electronic mode (E). For testing purposes the control system can be changed to the hydraulic operation mode (H). In case the electronic control system fails to work the hydraulic mode can be used for continuing operation. (8.1) Pilot oil filter 1 (8.2) Pilot oil filter 2 (9) Pressure accumulator for pilot oil circuit (10.1) Control and filter panel mounted on front PTO for engine 1 circuits, see page 209 for more information. (10.2) Control and filter panel mounted on rear PTO for engine 2 circuits 207 WARNING