OPERATION 3.7 ELECTRICAL EQUIPMENT IN CAB BASE 3.7.2 SWITCH BOARD (X2) IN CAB BASE Legend for illustration Z25818 Service switches (S27) Emergency By-pass switch for the shutdown func- tion of the PLC (E6). Switch positions: 0 - Normal operating position 1 - By-pass position If an automatic shutdown is initiated by Shovel sys- tems, with a dangerous situation for man or machine, which needs the Shovel to be operable to over-come the dangerous situation, set this switch to position (1) to override the shutdown function of the system and to enable a restart of the Diesel engines. REMARK This switch can not override engine initiated shutdowns.
As soon as the immediate situation of danger is over, shutdown the unit. Correct the fault that caused the shut down and re-set the Emergency By-pass switch (S27) to normal operating posi- tion (0). (S41.1) Switch for constant speed adjustment of engine 1 to 1800/min (rated speed) for testing purposes (S41.2) Switch for constant speed adjustment of engine 2 to 1800/min (rated speed) for testing purposes (S155) Service Switch for -QMIN- and -QMAX- Control of the Main Hydraulic Pumps REMARK The Service switch (S155) is used for testing and adjusting procedures of the hydraulic system and should only be operated through authorized ser- vice personnel. Switch positions:
0 - Normal operating position 1 - Qmax position: In this position the Qmin control is by-passed and the main pumps move to maximum delivery position. 2 - Qmin position: In this position the main pumps remain in Qmin position i.e. minimum oil delivery to the hydraulic system. NOTICE Make sure the switch (S155) is set to -0- position as soon as the testing and adjusting procedures of the hydraulic system are finished. 213 CAUTION CAUTION