Komatsu — 3.7.2 SWITCH BOARD (X2) IN CAB BASE

OPERATION 3.7 ELECTRICAL EQUIPMENT IN CAB BASE Checking active diagnostic Fault Codes of the engine control system QUANTUM and of the engine monitoring system CENSE REMARK With key switch in ON position, all six indicator lamps (H94.1/2) STOP, (H95.1/2) WARNING, and (H96.1/2) FLUID will illuminate together for approximately five seconds; then all six lamps will be turned off at the same if no faults are present. If active faults are present, then fault code flashout will start if the key switch is ON and the engines are off. QUANTUM faults will be flashed out on the red STOP indicator lamp and CENSE faults will be flashed out on the yellow WARNING indicator lamp.

The white FLUID lamp will remain on as long as a fault condition is present. To check for active fault codes proceed as follows: 1. Stop the engines and turn the Excavator main key switch to OFF position. 2. Turn the Excavator main key switch to ON position. 3. All active QUANTUM faults are flashed out first on the red STOP indicator lamp (H94.1 or H94.2). After all QUANTUM fault codes are flashed out, the active CENSE fault codes will be flashed out on the yellow WARNING indicator lamp (H95.1 or H95.2). The fault code flash out will begin with the first active QUAN- TUM fault.

The first digit will be flashed out (0.3 seconds between each flash), followed by a 1 second delay; then the second digit will be flashed out, followed by the third digit. There will be a 2 second delay before the next fault is flashed out. Once all QUANTUM fault codes are flashed out, CENSE fault codes will start to flash out on the yellow WARNING indi- cator lamp (H95.1 or H95.2). The same timing sequence, described above, is used for the CENSE faults. Once all faults have been displayed, there will be a 3 second delay before the fault code flashout begins again. Active faults MUST be corrected as soon as possible. Contact your Komatsu dealer for repair.

REMARK For more information, refer to the separate Engine Operation and Maintenance Manual filed in volume 2 binder. 217 CAUTION CAUTION