Komatsu — 3.7.2 SWITCH BOARD (X2) IN CAB BASE

OPERATION 3.7 ELECTRICAL EQUIPMENT IN CAB BASE Emergency Indication of Operating Conditions The ECS system is equipped with an emergency indication via LED’s on the Programmable Logic Controller PLC (E6), illustra- tion Z25819. In case of a malfunction of the text display in the operator’s cab, the LED’s on the PLC indicating failures in vital operating systems of the Shovel. The following faults are indicated: 219 Fault: LED No.: The ECS system is by-passed (By-pass switch S27 actuated) H30 Start of engine 1 and/or engine 2 blocked, resp. engine shifted to low idle speed by one or more of the eight high pressure filters. NOTICE The LED H31 monitors all eight high pressure filters.

Refer to page 221 for description of the diagnostic codes flashed out by LED H31. H31 Reserve H33 Reserve H34 Reserve H36 Start of both engines blocked, resp. engine shut down, due to closed main shut-off (gate) valve on hydraulic oil tank H37 Faulty monitor channel for hydraulic oil temperature H38 Too low hydraulic oil level! Stop the engines H39 Faulty monitor channel engine speed H112 Emergency shut down switch actuated H116 Engine shutdown from ground man (if so equipped) H135