Komatsu — 3.8 PREHEATING SYSTEMS FOR OIL, COOLANT AND BATTERIES

OPERATION 3.8 PREHEATING SYSTEMS FOR OIL, COOLANT AND BATTERIES Hydraulic Oil, PTO Gear Oil and Battery Heating Junction Box for Hydraulic Oil Heating and Location of Heat- ers and Thermostats, illustration Z25822 (1) Hydraulic oil reservoir (2) Junction box for hydraulic oil heating A - Switch, hydraulic oil heating ON/OFF. B - Warning light, heating system failure, C - Indicator light, hydraulic oil heating ON.

(3) Immersion heaters installed in the main and return oil reservoir (4) Thermostats installed in the main oil reservoir, suc- tion oil reservoir and in the PTO’s (pump distributor gears) (5) Immersion heaters installed in the suction oil reser- voir (6) Immersion heaters installed in the PTO’s (pump dis- tributor gears) (7) Heater plates for batteries 229