MAINTENANCE 4.9 EVERY 50 OPERATING HOURS OR WEEKLY 4.9.1 SWING GEARS AND MOTOR ADAPTER HOUSINGS - CHECK OIL LEVEL REMARK The machine can be equipped either with swing gears of manufacturer L&S or of manufacturer Siebenhaar . Refer to the data plate on each swing gear housing to find out the manufac- turer of the swing gears. Swing gears manufactured by L&S Legend for illustration Z22984 I Swing gear RH II Swing gear LH rear. This swing gear is accessible through the service door from the oil cooler side.
III Swing gear LH front Swing Gears (A) Position of oil level gauge for checking the oil levels (1) Oil level gauge (2) Oil filler pipe (3) Breather filter (7) Drain coupling or evacuation nozzles for Wiggins system Motor Adapter Housings (4) Oil level gauge and filler opening. This opening can also be used for connecting a suc- tion pump when changing the oil. (5) Breather filter (6) Oil drain plug CHECK SWING GEAR OIL LEVEL Remove oil level gauge (1) and wipe it clean. Insert the gauge but DO NOT screw in, see detail (A). Remove the gauge. The oil level should be at the upper mark of gauge (1). If necessary add the specified gear oil through filler opening (2). Remove breather filter (3).
Blow out with compressed air from inside to outside and reinstall. CHECK MOTOR ADAPTER HOUSING OIL LEVEL Remove oil level gauge (4) and wipe it clean. Insert the gauge but DO NOT screw in, see detail (A). Remove the gauge. The oil level should be at the upper mark of gauge (4). If necessary add the specified oil through filler opening (4). Remove breather filter (5). Blow out with compressed air from inside to outside and reinstall. 357