Komatsu — 4.9.6 MAIN HYDRAULIC OIL COOLER - INSPECT AND CLEAN IF NECESSARY

MAINTENANCE 4.9 EVERY 50 OPERATING HOURS OR WEEKLY ADDITIONAL HYDRAULIC OIL COOLER - INSPECT AND CLEAN IF NECESSARY See illustration Z 22592 Provide adequate working platform for safe access to the hydraulic oil coolers. Before removing mounting bolts (1) of the hydraulic oil cooler door (2) check to make sure that all door hinges are in good condition and properly fastened on their car- rier frames. If cracks are found at the welded joints of the hinges, DO NOT remove mounting bolts (1) otherwise the cooler door may become detached and fall off. Danger of accidents. Have the damage repaired as soon as possi- ble. 1. Loosen mounting bolts (1). 2. Open door (2). 3.

Swing out oil coolers (3 and 4). 4. Secure door (2) and oil coolers (3 and 4) with locking bars (6, 7 and 8). 5. Clean the oil coolers with compressed air. Direct the air flow from inside to outside. 6. After cleaning, bring back the oil coolers to their home posi- tion. PROCEED AS FOLLOWS Disengage locking bars (6, 7 and 8) and place them into the holders on top of the cooler frames (3 and 4) and carrier (5). Swing back inner cooler (5). Take care guide pin (A) fits into hole (B) of main frame (6). Secure cooler (5) with fastener (3). Swing back coolers (4 and 3). Close door (2). Install mounting bolts (1) and tighten securely.

NOTICE When cleaning the oil coolers, inspect also laying and fas- tening of the hydraulic oil lines. 371 WARNING WARNING