MAINTENANCE 4.11 EVERY 500 OPERATING HOURS OR QUARTELY 4.11.3 DRIVE SHAFT HOUSINGS ON PTO GEARS - CHECK OIL LEVEL Check oil level in all main- and secondary pump drive shaft housings, illustration Z20458A. Legend for illustration Z 20458A (A) Adapter housings for main hydraulic pumps (four on each gear (B) Adapter housings for secondary hydraulic pumps (10) Oil level plugs (11) Oil filler plug with breather pipe (12) Oil drain plug Check Oil Level in Drive Shaft Housings The Oil level should be at the lower edge of level plug opening (10). If necessary remove filler plug with breather pipe (11) and add Gear Oil through the filler opening up to the level opening (10).
Use the same type of oil as used in the pump distributor gear. Re-install plugs (10 and 11) and tighten securely. If pump removal becomes necessary, drain the drive shaft hous- ing oil by removing drain plug (12). Be sure to fill the drive shaft housing up to the filler opening (10) after mounting of the pump. NOTICE If oil starts dropping out at one of the breather pipes (11), the oil seal ring of the respective pump drive shaft must be checked and replaced if necessary. 393