Komatsu — 4.11.4 FUEL TANK - DRAIN CONDENSATION

MAINTENANCE 4.11 EVERY 500 OPERATING HOURS OR QUARTELY 4.11.4 FUEL TANK - DRAIN CONDENSATION Legend for illustration Z 20238 (1) Fuel tank breather valve on machines with refilling system (2) Main fuel shut-off cocks (3) Shut-off cock for pressure transducer (7). Close this cock when replacing the pressure transducer (7). (4) Protection cap for drain coupling (5) (5) Drain coupling (6) Hinged cover plates, swing down for access to fuel tank bottom (7) Pressure transducer for level indication DO NOT smoke or use an open flame when working around inflammable fuels. Drain Water and Sediments from Fuel Tank. Open the hinged covers (6) below the fuel tank.

Attach drain hose and open drain coupling (5). Collect outflowing sediments in a suitable container. Servicing the Fuel System. When servicing the fuel system close fuel shut-off cocks (2). NOTICE On machines equipped with a Fire Detection and Suppres- sion System, two solenoid valves are installed in place of the shut-off cocks (2). After finishing the service, open cocks (2) and vent the fuel sys- tem according to the engine maintenance manual. Check to make sure all fuel lines and connections are in good condition. Check the complete fuel system for leaks. 395 WARNING WARNING