Komatsu — 4.12.1 HIGH STRENGTH BOLT CONNECTIONS - CHECK TORQUE LOAD

MAINTENANCE 4.12 EVERY 1000 OPERATING HOURS OR EVERY 6 MONTH High-Strength Bolt Connections (continued) Check fastening and condition of the machinery house posts and roof carrier frame, illust. Z 22631 Reference No.: Qty. (1) 24 (2) 24 (3) 8 (4) 48 (1) (5) 48 * SW = Wrench size Re-tighten loose mounting bolts and replace missing or dam- aged bolts. (1) These bolts are secured with self locking nuts (5). 421 Bolt size mm Grade SW * mm Tightening torque Nm M20 10.9 30 510 M30 10.9 46 1770 M24 10.9 36 880 M20 10.9 30 510 Self locking nut M20 8 30 Check for loose- ness. Replace nuts which have lost their clamping torque.