MAINTENANCE 4.12 EVERY 1000 OPERATING HOURS OR EVERY 6 MONTH High-Strength Bolt Connections (continued) Check condition and fastening of all three swing gears (01) and swing motors (02), illust. Z 22514 Reference No.: Qty. ** (8) 24 (25) Socket head cap bolts 102 * SW = Wrench size ** Quantity for all three swing gears REMARK After checking and retightening of swing gear mounting bolts (25), attach protection caps (26) onto the bolt heads. 433 Bolt size mm Grade SW * mm Tightening torque Nm M 16 10.9 24 265 M 24 12.9 19 1030