Komatsu — 4.12.1 HIGH STRENGTH BOLT CONNECTIONS - CHECK TORQUE LOAD

MAINTENANCE 4.12 EVERY 1000 OPERATING HOURS OR EVERY 6 MONTH High-Strength Bolt Connections (continued) Check condition and fastening of travel gears, final drives and track rollers, illustration Z21206 Check tightening torque of mounting bolts as indicated in the illustration. Re-tighten mounting bolts to their correct torque and replace missing or damaged bolts. REMARK If the outer bolts (1) have been found loose it is necessary to check also the inner bolts (2) for looseness. This checking proce- dure requires removal of the travel gear. Contact your Komatsu service for assistance. 443