Komatsu — 4.12.2 HYDRAULIC SYSTEM - FILTER SERVICE

MAINTENANCE 4.12 EVERY 1000 OPERATING HOURS OR EVERY 6 MONTH 4.12.2 HYDRAULIC SYSTEM - FILTER SERVICE Replace elements of the seven return oil filters (R) and of the single leakage oil filter (L). Clean screens. REMARK Prior to servicing the filters transfuse the oil from the return reservoir into the main oil reservoir, refer to page 279 for transfu- sion procedure. Follow the steps shown in illust. (Z 21112A): 1. Loosen bolt (1). 2. Turn retainer (2). 3. Remove cover assy (3). Inspect O-ring (4) and replace if nec- essary. 4. Attach lifting rope and lift out element assy (5). 5. Disassemble filter assy (5) in sequence of ref. nos. (6 to 12). 6. Discard element (8). 7.

Inspect screen (11) and clean if necessary. Take care not to contaminate the clean inside of the screen when flushing. 8. Inspect screen (11) and O-ring (12) for damage replace if necessary. Install screen (11) use new sealing washer (10) and self lock- ing nut (9). 9. Reassemble filter assy (5) with new element (8) according to step 5. Use new self locking nuts (6). 10. Install filter assy use new gasket (7). Torque bolt (1) to 850 Nm. NOTICE After each repair of the hydraulic system the elements (8) should be replaced after about 50 hours. The filter elements must also be replaced when the fault message ”Return oil filter restricted” is being displayed on the ECS screen.

Replace screens (11) every 5000 operating hours at the latest. 449