Komatsu — 4.12.2 HYDRAULIC SYSTEM - FILTER SERVICE

MAINTENANCE 4.12 EVERY 1000 OPERATING HOURS OR EVERY 6 MONTH FILTER SERVICE Clean or replace pressure filter elements, illust. Z 22873, as follows: 1. Place working equipment on the ground and shut-off the engines. Relieve pressure in the hydraulic system according to page 270 in the operation section. 2. Place a suitable container below the filter in order to collect outflowing oil. 3. Unscrew case (C) of the respective filter and clean the filter case. NOTICE Carefully inspect elements for damage. Always install new elements if ruptures or other damages are found. 4. Remove element (F) and clean. Take care not to contaminate the "Clean" inside of the element when flushing. 5.

Inspect O-rings and back-up ring. Replace if necessary. 6. Install drain plug with new packing ring. 7. Lubricate the thread at the filter head and at filter case (C) with multi-purpose grease K2K. 8. Insert the cleaned element or a new element (F) with new O- ring (G). 9. Fill the case (C) of the hydraulic oil filters (8.1, 8.2, 12.1, 12.2, 13.1, and 13.2) half way up with clean hydraulic oil. 10. Fill the case (C) of the PTO gear oil filters (11.1 and 11.2) half way up with clean gear oil. 11. Screw the case (C) into the head and tighten. 12. After short operating period check filter for leakage. 13. Check restriction indicator (H) for proper mounting and good condition.

NOTICE Replace elements (F) after three cleanings or after every 5000 operating hours, whichever occurs first. 457