Komatsu — 4.12.2 HYDRAULIC SYSTEM - FILTER SERVICE

MAINTENANCE 4.12 EVERY 1000 OPERATING HOURS OR EVERY 6 MONTH FILTER SERVICE Replace elements of the three breather filters (1), illustration Z21116 1. Remove nut (2), cover (3) and element (4). 2. Insert new element (4) and reassemble filter unit (1). Clean filler screen (6) 1. Remove cover (5). 2. Take out screen (6) with gaskets (7). 3. Clean the screen and inspect for damage. Use a new screen if necessary. 4. Install screen (6) with new gaskets (7). 5. Install cover (5). 459