MAINTENANCE 4.13 EVERY 2000 OPERATING HOURS OR YEARLY 4.13.1 HYDRAULIC SYSTEM - CHANGE OIL, REPLACE SUCTION STRAINERS AND PULSATION DAMPER The hydraulic oil change intervals can be extended for a further time period, when an oil sample analysis shows a positive result. When extending the oil change interval, it is necessary to carry out an oil sample analysis after every 1000 operating hours. However, it is recommended to change the hydraulic oil after 6000 operating hours at the latest. NOTICE The pulsation damper of the hydraulic oil cooler circuit must be replaced after every 2000 operating hours. See ref. no. (13) in illustration (Z22608) on page 477.
Oil flow in the hydraulic oil reservoirs, typical illustration, (Z 19462): (1) Main oil reservoir (2) Main shut-off valve (3) Compensator (4) Suction strainer (5) Suction oil reservoir (6) Pump distributor gear (7) Main hydraulic pump (8) Return oil collector pipe (9) Back pressure valve (10) Return oil compartment (11) Return oil filters (12) Shut-off valves, transfer pump (13) Transfer pump (14) Oil level sight gauge 473