MAINTENANCE 4.13 EVERY 2000 OPERATING HOURS OR YEARLY Hydraulic System – Change Oil, illustration (Z 22599A): 1. With the hydraulic oil at operating temperature, park the machine on level ground. 2. Lower the attachment to the ground with the stick fully retracted and the bucket fully rolled back as shown on the oil level plate. 3. Stop the engines. Relieve pressure in the hydraulic system according to the instructions on page 270. 4. Connect evacuation hose from service truck to the evacuation adapter on the central refilling panel on the swing down ser- vice arm, see page 284 for more information. Switch on the evacuation pump. 5.
Transfuse the oil from return oil compartment into the main reservoir (7). Open valve (1), position ”0”. Remove vent plugs (8) and (17) on main hydraulic oil reservoir. Switch on transfer pump (5) with switch (4). When the return oil compartment is empty, switch off pump (5) and close valve (1), position (C). 6. Transfuse the oil from return oil collector pipe (9) into the main reservoir. Open valve (2), position ”0”. Switch on transfer pump (5) with switch (4). When the return oil collector pipe is empty, switch off pump (5) and close valve (2), position (C). 7. Transfuse oil from suction oil reservoir into main reservoir (7). Close main shut-off valve with hand wheel (10).
Open valve (3), position ”0”. Open the vent screws (12) on the suction flange of the main pumps on both pump distributor gears to prevent vacuum in the suction oil reservoir and lines. Switch on transfer pump (5) with switch (4). When the suction oil reservoir is empty, switch off pump (5) and close valve (3), position (C). 8. After the hydraulic oil reservoir is completely evacuated switch off the evacuation pump of the service truck and dis- connect the evacuation hose from evacuation adapter on the central refilling panel. 9. Install vent plugs (8) and (17) and tighten securely. 10. Open the main shut-off valve with hand wheel (10) 11.
Service the return oil filters and inspect reservoir for sedi- ments, clean if necessary. 12. Replace filler screen, suction strainers and pulsation damper according to the instructions on the following pages. 475