Komatsu — 4.13.1 HYDRAULIC SYSTEM - CHANGE OIL, REPLACE SUCTION STRAINERS AND PULSATION DAMPER

MAINTENANCE 4.13 EVERY 2000 OPERATING HOURS OR YEARLY HYDRAULIC SYSTEM - REPLACE SUCTION STRAINER (6), FILLER SCREEN (11) AND PULSA- TION DAMPER (13), ILLUSTRATION Z22608 1. Replace suction strainer (6) of suction oil reservoir ”B”. Install new screen (6) with new gaskets (5 and 7). Install intermediate pipe (3). Install inspection cover (3a) with new gasket. Make sure compensator (8) is properly fitted. See page 441 for mounting instructions. 2. Remove pulsation damper (13), located on the bottom flange of collector pipe (C). Install new pulsation damper (13) with new O-ring. 3. Make sure main shut-off valve (A) is completely open. 4. Replace filler screen (11): Remove cover (10).

Take out screen (11) with gaskets (12) and discard. Install new screen (11) with gaskets (12). Install cover (10) with filler plug (9). REMARK Replace strainer (17) of the hydraulic oil cooler circuit after major repairs on the hydraulic system and after every 6000 oper- ating hours. Proceed as follows: Remove bolts (14 and 15). Remove pipe (18) with strainer (17). Take out strainer (17) from pipe (18) and discard. Discard gaskets (16 and 19). Insert new strainer (17) with new gaskets (16) into pipe (18). Install pipe (18) with new gasket (19) into return oil collector pipe (C). Use new self locking nuts and tighten bolts (14 and 15) securely. 5.

Replace the eight suction strainers of the main pumps, see next page for more information. 477