Komatsu — 4.13.1 HYDRAULIC SYSTEM - CHANGE OIL, REPLACE SUCTION STRAINERS AND PULSATION DAMPER

MAINTENANCE 4.13 EVERY 2000 OPERATING HOURS OR YEARLY HYDRAULIC SYSTEM - REPLACE SUCTION STRAINERS OF THE EIGHT MAIN HYDRAULIC PUMPS 1. Remove bolts (1). 2. Push away flange (2) with suction hose (3) from strainer (5). 3. Take out strainer (5) with gaskets (4) and discard. 4. Insert new strainer (5) with new gaskets (4) into the suction reservoir opening. 5. Align flange (2) with strainer (5). 6. Insert bolts (1) and tighten with new self locking nuts (6). 479