Komatsu — 4.13.1 HYDRAULIC SYSTEM - CHANGE OIL, REPLACE SUCTION STRAINERS AND PULSATION DAMPER

MAINTENANCE 4.13 EVERY 2000 OPERATING HOURS OR YEARLY HYDRAULIC SYSTEM - FILL THE OIL RESER- VOIRS AND REMOVE AIR FROM THE SYSTEM Hydraulic Oil Viscosity Select hydraulic oil viscosity grade according to ambient tempera- tures. If the new hydraulic oil has a different viscosity grade com- pared with the drained oil it is necessary to enter the new viscosity grade into the appropriate ”Service SETTINGS” group of the ECS Menu Control. Refer to the page 129 for the INPUT procedure of the oil viscosity. Filling procedure: 1. Connect hydraulic oil supply line from service truck to the fill- ing adapter on the central refilling panel of the swing down service arm.

Proceed according to the instructions on page 289. Be sure the main shut-off valve (10), illust. Z22599A is open. 2. With the hydraulic oil reservoir filled up to the correct level remove the air from the system. Remove air from the hydraulic system, illust. Z 22599A: 1. Open vent plugs (12) on the pump suction ports of all eight main pumps (11) and on the four gear type pumps (16). As soon as bubble free oil flows out tighten the vent plugs (12). 2. Open the vent plugs on top of both axial piston pumps (15). 3. As soon as bubble free oil flows out tighten the vent plugs on both axial piston pumps (15). Check oil level in the eight main pump housings: 1.

Remove oil level and filler plug (13). The oil level in the pump housing should reach the lower edge of the opening. The port (14) of the leakage oil return line can also be used for checking and filling of the pump housing. 2. If necessary add hydraulic oil up to the lower edge of the filler opening. 3. Insert and tighten filler plug (13) respectively connect leakage oil return line to port (14). Make sure the main pump housings are correctly filled, other- wise the pump drive shaft bearings could be damaged due to lack of lubrication. Final checks: Check hydraulic oil level and check the complete system for leak- age; especially the connection between main oil and suction oil reservoir.

Make sure the main shut-off valve is completely open. Start the engines and perform several operating cycles without load to remove residual air from the system. Re-check hydraulic oil level. 481