Komatsu — 4.13.2 EMERGENCY ESCAPE LADDERS - INSPECTION

MAINTENANCE 4.13 EVERY 2000 OPERATING HOURS OR YEARLY Emergency Escape Ladder and Escape Hatch in the Machinery House Legend for illust. Z25294 (A) Emergency escape ladder on Operator’s cab plat- form. (B) Emergency escape ladder on superstructure plat- form. (C) Emergency escape ladder on upper deck. (D) Emergency escape ladder with escape hatch on counterweight, see view -E- for details. (E) Counterweight with emergency escape ladder viewed from inside machinery house. (1) Emergency escape ladder on counterweight (2) Fastener for escape hatch (3) (3) Escape hatch (4) Openings in the counterweight.

In case of a fire in the machinery house, these openings can be used for pouring fire extinguishing agent into the machin- ery house. Check emergency escape ladder (1) for good condition and proper fastening. Check to make sure that the escape hatch (3) can freely be moved. If any damage or bad condition is found, replace the con- cerned part without delay. 489