Komatsu — 4.14.1 SWING GEARS AND MOTOR ADAPTER HOUSING - CHANGE OIL

MAINTENANCE 4.14 EVERY 3000 OPERATING HOURS HOWEVER AT LEAST ONCE A YEAR 4.14.1 SWING GEARS AND MOTOR ADAPTER HOUSING - CHANGE OIL Swing Gears made by -L&S- Legend for illustration Z22984 I Swing gear RH II Swing gear LH rear. This swing gear is accessible through the service door from the oil cooler side. III Swing gear LH front Swing Gears (A) Position of oil level gauge for checking the oil levels (1) Oil level gauge (2) Oil filler pipe (3) Breather filter (7) Drain coupling or evacuation nozzles for Wiggins system Motor Adapter Housings (4) Oil level gauge and filler opening. This opening can also be used for connecting a suc- tion pump when changing the oil.

(5) Breather filter (6) Oil drain plug Swing Gears, change oil: 1. Use adequate working platform for draining the oil. Place receptacles of sufficient capacity (approx. 65 liter) below drain coupling (7). Attach drain hose (part of tool set) to drain cou- pling (7). Remove parts (1, 2 and 3) to speed up draining. 2. Clean breather filter (3) with compressed air from inside to outside and re-install. 3. After the oil is completely drained, flush the gear with the reg- ular gear oil. 4. Remove drain hose from coupling (7) and attach the protec- tion cap onto the drain coupling. 5. Fill gear housing through filler opening (2) with fresh gear oil up to the MAX mark on level gauge (1).

Install plug (2). NOTICE For checking the oil level insert level gauge (1) but do not screw in, see detail (A). 6. Insert gauge (1) and tighten securely. 7. After short operating period check oil level and housings for leakages. 491