MAINTENANCE 4.14 EVERY 3000 OPERATING HOURS HOWEVER AT LEAST ONCE A YEAR 4.14.3 FINAL DRIVE HOUSINGS - CHANGE OIL See illustration Z20455 1. Loosen mounting bolt (2) and remove hood (1). 2. Remove the filler plug (4). 3. Unscrew the breather filter (5). 4. Blow out the breather filter (5) with compressed air from the inside to outside and re-install. 5. Remove drain plug (6) and drain the lubricating oil. 6. After the oil is completely drained, install the cleaned drain plug (6) and tighten securely. 7. Fill in new oil up to the ”MAX” marking on oil level gauge (3). 8. Clean the filler plug (4) and reinstall. 9. After short operating period check oil level and gear for leaks. 503