Komatsu — 4.14.4 PTO (PUMP DISTRIBUTOR GEAR) - CHANGE OIL

MAINTENANCE 4.14 EVERY 3000 OPERATING HOURS HOWEVER AT LEAST ONCE A YEAR 4.14.4 PTO (PUMP DISTRIBUTOR GEAR) - CHANGE OIL Legend for illustration Z 21104 (1) Oil level gauge (2) Oil filler plug (3) Breather filter (4) Oil level sight gauge (oil level should be at the center line of sight gauge) (5) Oil drain coupling Gear Oil Viscosity Select gear oil viscosity grade according to ambient tempera- tures. If the new gear oil has a different viscosity grade compared with the drained oil it is necessary to enter the new viscosity grade into the appropriate ”Excavator Components” group. Refer to page 139 for the INPUT procedure of the oil viscosity.

NOTICE Before opening the access covers from below the pump dis- tributor gears provide an adequate working platform with sufficient space for the oil collecting container (approx. 280 liters for both gears). Change the oil 1. Attach drain hose (part of tool set) to drain coupling (5). 2. Remove gauge (1) and filler plug (2). 3. Remove breather filter (3), blow out with compressed air from inside to outside and re-install. 4. After the oil is completely drained, flush the gear with the reg- ular gear oil. 5. Remove drain hose from coupling (5) and attach the protec- tion cap onto the coupling. 6. Fill in new oil through opening (2) up to the “MAX” mark on gauge (1). 7.

Re-install parts (1 and 2). After short operating period, check oil level and housing for leakage. REMARK If the oil level is above the "MAX" mark, drain the oil down until the oil level is at the "MAX" mark. Too much oil in the pump distributor gear will cause aeration of the oil. 505