OPERATION 3.4 ELECTRONIC MONITORING AND CONTROL SYSTEM ECS Legend for illust. Z25816 (A) Display with basic information (B) Key board with 8 keys. For the function of the keys refer to page 99. (C)) Key operated switch for enabling access to the INPUT-OUTPUT levels and input of operational data. (D) Key section with 4 keys for menu control of Service Functions and for INPUT- OUTPUT functions (On Screen Display). (E) Plug socket for connecting remote printer or other data downloading equipment. For printing out the contents of the Statistics memory, press key (8) and key (6).For printing out the contents of the Protocol memory, press keys (7, 6 and 3).
Keep key (3) depressed until all messages are selected and then press key (6) two times. Refer also to page 121 for more detailed information. (9) RETURN Key, this key is used for returning to previous level of INPUT-OUTPUT or Service Functions. (10) QUI Key, this key is used for access to the next lower level of INPUT-OUTPUT or Service Functions and going back to the Standard Display from a displayed cur- rent message. (11) -0- Key, this key is used for selection of horizontal menu items within a main sec- tion of the inputs-outputs or service levels (LH direction). (12) -1- Key, same function as key (11) but in RH direction.
Refer to page 131 Menu Control, for more information about the key section (D). (13) Acoustic warning signal (Buzzer) This signal is heard for approximately 1 second when a fault message appears on screen (B). Continuous sound when the hydraulic oil level is too low. In case of too low hydraulic oil level this signal sounds continuously. Shut down the Shovel, locate and correct the cause immediately. Fill up hydrau- lic oil to the correct level. (14) High level alarm: Automatic engine shutdown . The high level alarm (14) will sound approximately 10 seconds before an auto- matic engine shutdown occurs and will continue to sound during the 10 second period.
At the same time a blinking message *SHUTDOWN* will be displayed on the ECS screen. Use the time period to move the machine to a safe place and lower the attachment to the ground. Inform service about the shutdown condition. (15) Switch for truck counter on RH control lever. The loaded trucks can be counted by actuating this switch. The total number of trucks loaded will then be displayed on screen (A) for five seconds. 97 CAUTION WARNING